Copper-core PVC-insulated and sheathed copper-braided shielded twisted pair RVVPS

Copper-core PVC-insulated and sheathed copper-braided shielded twisted pair RVVPS
+
  • Copper-core PVC-insulated and sheathed copper-braided shielded twisted pair RVVPS

  • Product Description
  • Specification Parameters
  • Download Materials
    • Commodity name: Copper-core PVC-insulated and sheathed copper-braided shielded twisted pair RVVPS

    Cables for connecting and wiring applications in household appliances, small electric tools, instruments, electronic devices, automation systems, and power and lighting installations, with shielding requirements, rated at 300/300V or lower.

    Use

     

    Cables used for connecting and wiring appliances, small electric tools, instruments, electronic devices, automation systems, and power and lighting installations with rated voltages of 300/300V or lower, where shielding is required.

     

    Main features

     

    Ambient temperature: 0℃ to 40℃ (for mobile installation); during short circuits (within 5 seconds), the maximum conductor temperature shall not exceed 70℃.
    Bending radius: For cables with an outer diameter of 25 mm or less, the bending radius should be no less than 4 times the cable’s outer diameter; for cables with an outer diameter of 25 mm or more, the bending radius should be no less than 6 times the cable’s outer diameter.
    Material requirements: The conductor shall be a bare copper circular flexible conductor conforming to GB/T 3956-2008/IEC 60228:2004 and JB/T 8734.3-2016; the insulation shall be PVC/D type conforming to GB/T 5023.1-2008/IEC 60227-1:1997; the shielding shall be made of braided copper wire; and the jacket shall be PVC/ST5 type.

     

    Structural Diagram

     

     

  • Model

    Rated voltage

    Specifications mm 2

    Nominal insulation thickness mm

    Nominal thickness of the jacket mm

    Approximate outer diameter mm

    20 Celsius Maximum DC resistance of the conductor Ω/km

    Approximate weight

    kg/km

    Minimum insulation resistance at the conductor’s maximum operating temperature

    MΩ·km

    Implementation standard

    RVVPS

    300/300V

    2 × 2 × 0.2

    0.4

    0.8

    7.4

    97.8

    63.3

    0.013

    JB/T 8734.5-2016

    2 × 2 × 0.3

    0.5

    0.6

    8.4

    73.4

    80.5

    0.014

    2 × 2 × 0.4

    0.5

    0.8

    8.9

    51.1

    91.5

    0.013

    2 × 2 × 0.5

    0.5

    0.9

    9.3

    41.4

    100.2

    0.012

    2 × 2 × 0.75

    0.5

    1.0

    10.1

    27.6

    123.3

    0.010

    2 × 2 × 1.0

    0.6

    1.0

    11.3

    20.7

    254.6

    0.010

    2 × 2 × 1.5

    0.6

    1.0

    Keywords:

    Copper-core PVC-insulated and sheathed copper-braided shielded twisted pair RVVPS
    +
    • Copper-core PVC-insulated and sheathed copper-braided shielded twisted pair RVVPS

    Copper-core PVC-insulated and sheathed copper-braided shielded twisted pair RVVPS


    Cables for connecting and wiring applications in household appliances, small electric tools, instruments, electronic devices, automation systems, and power and lighting installations, with shielding requirements, rated at 300/300V or lower.

    Product Category


    Content update in progress,...

    Online Message


    If you are interested in our business or would like to learn more,

    You're welcome to leave us a message, and we'll get in touch with you as soon as possible.

    Submit