Copper-core halogen-free low-smoke insulation and halogen-free low-smoke sheathed flexible cable WD(Z/ZC/ZB/ZA)-series RYY and RYJY

Copper-core halogen-free low-smoke insulation and halogen-free low-smoke sheathed flexible cable WD(Z/ZC/ZB/ZA)-series RYY and RYJY
+
  • Copper-core halogen-free low-smoke insulation and halogen-free low-smoke sheathed flexible cable WD(Z/ZC/ZB/ZA)-series RYY and RYJY

  • Product Description
  • Specification Parameters
  • Download Materials
    • Commodity name: Copper-core halogen-free low-smoke insulation and halogen-free low-smoke sheathed flexible cable WD(Z/ZC/ZB/ZA)-series RYY and RYJY

    For power connection of household appliances, small electric tools, instruments and meters, as well as power and lighting installations with rated voltages of 300/500V and below.

    Use

     

    Used for connecting power supplies to household appliances, small electric tools, instruments and meters, as well as power and lighting installations with rated voltages of 300/500V and below.

     

    Main features

     

    Ambient temperature: The ambient temperature during installation must not be lower than 0℃.
    Bending radius: For cables with an outer diameter of 25 mm or less, the bending radius should be no less than 4 times the cable’s outer diameter; for cables with an outer diameter of 25 mm or more, the bending radius should be no less than 6 times the cable’s outer diameter.
    Material requirements: The conductor shall be a bare copper circular flexible conductor conforming to GB/T 3956-2008/IEC 60228:2004 and JB/T 8734.3-2016. The insulation and sheath shall comply with the requirements of GB/T 32129-2015. The corresponding materials are listed in the table below.

     

    Model

    Voltage level

    Insulation material code

    Sheath material code

    Temperature rating

    WD(Z/ZC/ZB/ZA)-RYY

    300/500V

    WDZ-Y-J70

    WDZ-Y-H70

    70℃

    WD(Z/ZC/ZB/ZA)-RYJY

    WDZ-YJ-J90

    WDZ-Y-H90

    90℃

     

    Structural Diagram

     

     

  • Model

    Specifications mm 2

    Nominal insulation thickness mm

    Nominal thickness of the jacket mm

    Approximate outer diameter mm

    20 Celsius Maximum DC resistance of the conductor Ω/km

    Approximate weight

    kg/km

    Minimum insulation resistance at the conductor’s maximum operating temperature

    MΩ·km

    WD(Z/ZC/ZB/ZA)-RYY

    WD(Z/ZC/ZB/ZA)-RYJY

    2 × 0.5

    0.4

    0.6

    5.2

    39.0

    32.9

    0.012

    3 × 0.5

    0.4

    0.6

    5.5

    39.0

    41.1

    0.012

    10 × 0.5

    0.4

    1.0

    9.5

    39.0

    116.7

    0.012

    12 × 0.5

    0.4

    1.0

    9.8

    39.0

    130.9

    0.012

    20 × 0.5

    0.4

    1.2

    12.0

    26.0

    207.3

    0.011

    2 × 0.75

    0.4

    0.6

    5.6

    26.0

    40.1

    0.010

    3 × 0.75

    0.4

    0.6

    5.9

    26.0

    50.9

    0.010

    4 × 0.75

    0.4

    0.8

    7.4

    26.0

    77.3

    0.0037

    5 × 0.75

    0.4

    0.9

    Keywords:

    Copper-core halogen-free low-smoke insulation and halogen-free low-smoke sheathed flexible cable WD(Z/ZC/ZB/ZA)-series RYY and RYJY
    +
    • Copper-core halogen-free low-smoke insulation and halogen-free low-smoke sheathed flexible cable WD(Z/ZC/ZB/ZA)-series RYY and RYJY

    Copper-core halogen-free low-smoke insulation and halogen-free low-smoke sheathed flexible cable WD(Z/ZC/ZB/ZA)-series RYY and RYJY


    For power connection of household appliances, small electric tools, instruments and meters, as well as power and lighting installations with rated voltages of 300/500V and below.


    Content update in progress,...

    Online Message


    If you are interested in our business or would like to learn more,

    You're welcome to leave us a message, and we'll get in touch with you as soon as possible.

    Submit