logo

>
produc_details
Photovoltaic Cable - Tinned Copper Conductor
1/1
Number of views:
1000

Photovoltaic Cable - Tinned Copper Conductor

This product is suitable for photovoltaic systems and is suitable for use under Class II safety level. The ambient temperature of the cable operation is up to 90°C, and the maximum operating temperature of the conductor does not exceed 120°C. Multiple cables can be used in parallel.
Number of views:
1000
Quantity
-
+
1
Description
Specification
Download

Description

Use

 

This product is suitable for photovoltaic systems and is suitable for use under Class II safety level. The ambient temperature of the cable operation is up to 90°C, and the maximum operating temperature of the conductor does not exceed 120°C. Multiple cables can be used in parallel.

 

Installation Notes

 

This product should be used with the specified appropriate terminal connections.
This product is suitable for fixed installation, interconnection of modules in photovoltaic strings, series connection of combiner boxes, etc.
If this product needs to be laid in the ground or exposed to the sun, it should be protected such as wearing a pipe. When using a metal pipe and only 1-core cable, the metal pipe must be non-magnetic.

 

main features

 

Ambient temperature: -40°C~120°C (mobile or fixed).
Bending radius: not less than 4 times the outer diameter of the cable.
The conductor adopts the fifth kind of tinned copper flexible conductor, and the insulation and sheath are made of 125°C halogen-free, low-smoke, flame-retardant cross-linked polyolefin material, which has been irradiated and cross-linked by a high-energy electron accelerator. The finished cable has excellent weather resistance and UV resistance Light and ozone erosion, adapt to a wider range of temperature changes (-40 ° C ~ 120 ° C).

 

Structural representation

 

Scan the QR code to read on your phone

Specification

model

Rated voltage

Specification

mm 2

Insulation Thickness

mm

Sheath thickness

mm

Average outer diameter

mm

Conductor DC resistance at 20 ℃ Ω/km

Cable Approximate Weight

Kg/km

Executive standard

H1Z2Z2-K

DC 1.5 kV    AC 1.0/1.0kV

1×1.5

0.7

0.8

4.5

13.7

32.4

EN 50618 2014

1×2.5

0.7

0.8

4.9

8.21

43.2

1×4

0.7

0.8

5.4

5.09

59.6

1×6

0.7

0.8

5.9

3.39

79.0

1×10

0.7

0.8

7.2

1.95

122.4

1×16

0.7

0.8

8.3

1.24

178.1

1×25

0.9

1.0

10.5

0.795

279.2

1×35

0.9

1.1

11.8

0.565

374.3

The above cables can be customized into two-core 8-shaped detachable according to requirements.

model

Rated voltage

Specification

mm 2

Insulation minimum thickness

mm

The thinnest thickness of sheath

mm

Average outer diameter

mm

Conductor DC resistance at 20 ℃ Ω/km

Cable Approximate Weight

Kg/km

Executive standard

PV1-F

DC 1.8kV

AC 0.6/1kV

1×1.5

0.5

0.5

4.1

13.7

29.6

2 PfG 1169 08.07

1×2.5

0.5

0.5

4.5

8.21

40.1

1×4

0.5

0.5

5.1

5.09

54.7

1×6

0.5

0.5

5.7

3.39

73.7

1×10

0.5

0.5

7.2

1.95

122.9

1×16

0.5

0.5

8.3

1.24

178.8

1×25

0.5

0.5

10.5

0.795

280.3

1×35

0.5

0.5

12.0

0.565

381.1

The above cables can be customized into two-core 8-shaped detachable according to requirements.

model

Rated voltage

Specification

mm 2

Insulation Thickness

mm

Sheath thickness

mm

Average outer diameter

mm

Conductor DC resistance at 20 ℃ Ω/km

Cable Approximate Weight

Kg/km

Executive standard

62930 IEC131

DC 1.5kV

1×1.5

0.7

0.8

4.5

13.7

31.0

IEC 629302017-12

1×2.5

0.7

0.8

4.9

8.21

41.5

1×4

0.7

0.8

5.4

5.09

57.5

1×6

0.7

0.8

6.0

3.39

76.56

1×10

0.7

0.8

7.2

1.95

119.4

1×16

0.7

0.9

8.5

1.24

178.3

1×25

0.9

1.0

10.5

0.795

273.4

1×35

0.9

1.1

11.8

0.565

367.5

The above cables can be customized into two-core 8-shaped detachable according to requirements.

model

Rated voltage

Specification

mm 2

Insulation Thickness

mm

Sheath thickness

mm

Average outer diameter

mm

Conductor DC resistance at 20 ℃ Ω/km

Cable Approximate Weight

Kg/km

Executive standard

GF-WDZEER-125

AC  0.6/1kV

1×1.5

0.7

0.8

4.5

13.7

31.0

NB T 42073-2016

1×2.5

0.7

0.8

4.9

8.21

41.5

1×4

0.7

0.8

5.4

5.09

57.5

1×6

0.7

0.8

6.0

3.39

76.6

1×10

0.7

0.8

7.2

1.95

119.4

1×16

0.7

0.9

8.5

1.24

178.3

1×25

0.9

1.0

10.5

0.795

273.4

1×35

0.9

1.1

11.8

0.565

367.5

DC 1.8kV

1×1.5

0.7

0.8

4.5

13.7

31.7

1×2.5

0.7

0.8

4.9

8.21

42.3

1×4

0.8

0.8

5.6

5.09

60.7

1×6

0.8

1.0

6.6

3.39

85.0

1×10

0.8

1.0

7.8

1.95

130.6

1×16

1.0

1.1

9.5

1.24

199.3

1×25

1.0

1.2

11.1

0.795

289.8

1×35

1.0

1.2

12.2

0.565

380.1

 

model

Rated voltage

Specification

mm 2

Insulation Thickness

mm

Sheath thickness

mm

Average outer diameter

mm

Conductor DC resistance at 20 ℃ Ω/km

Cable Approximate Weight

Kg/km

Executive standard

GF-WDZEESR-125

DC 1.8kV

2×4

0.8

0.8

5.6×12.2

5.09

133.5

NB T 42073-2016

2×6

0.8

1.0

6.6×14.0

3.39

187.0

Download

Previous