SM-11-A

Dedicated circuit design. Ensure that the elevator runs safely when the door is opened in advance and when the door is re-leveled. Safety relays are used. Different metal materials are used on the first pair of contacts to ensure that they will not stick. Modular design, suitable for standard production, and reducing wiring error rates Standard guide rail card slot bottom shell, convenient for control cabinet installation
Number of views:
1000
Quantity
-
+
1
Description
Specification
Download

Description

Product Features

dedicated circuit design. To ensure that the elevator runs safely when the door is opened in advance and when the door is re-leveled. Safety relays are used. Different metal materials are used on the first pair of contacts to ensure that they will not stick. Modular design, suitable for standard production, reducing wiring error rates. Standard guide rail card slot bottom
shell , to facilitate the installation of the control cabinet
Follow the requirements of EN81 and GB7588, pass CE certification, TUV certification, and elevator safety circuit certification with electronic components

 

Function Description

The function of opening the door in advance and re-leveling after opening the door
The function of preventing the car from moving unexpectedly
The function of detecting the short circuit of the door circuit

 

product configuration

It can be configured for all control cabinets of Xinshida

Keyword:
Elevator computer board
Elevator control system
Elevator control panel
Scan the QR code to read on your phone

Specification

Technical indicators
Power supply: single-phase 200V, 3.7KW (16.5A);
three-phase 400V, 5.5KW (11.5A)
motor: synchronous/asynchronous
brake: DC<2.5A
door operator: AC220V frequency conversion door operator
control method: single elevator/ Parallel
intercom: five parties (one-key dialing in the car)
Lighting: AC220V
Optional: Internet of Things, one-key call and other functions

 

Standard STO module

 

Main features
SIL3 level certification
meets IEC61800-3 & IEC61326-3-1 standards and new national standard EMC requirements.
Replace the main contactor;
adopt dual-channel topology, high reliability;
with fault detection function (random failure and system failure), size (mm): vertical cabinet 1200x200x100; horizontal cabinet 650x360x100
high safety integrity

Download